Intracranial Complex ruptured aneurysms coiled with overlapping LVIS stent.
World Neurosurg. 2019 Jan 07;:
Authors: Yan Z, Zheng K, Xiong Y, Lan F, Wang Y, Tan X, Zhong M, Li Z
Abstract
BACKGROUND: Overlapping stents represent a new paradigm in endovascular interventions, especially for complex and wide-necked aneurysms. The low-profile visualized intraluminal support (LVIS) device is a new generation of self-expanding braided stents recently introduced in China for stent-assisted coiling of intracranial aneurysms. We report several cases of intracranial aneurysms coiled using overlapping LVIS stents to evaluate its efficacy and safety.
METHODS: Patients with ruptured intracranial aneurysms treated with double LVIS stents at our centre between November 2014 and May 2016 were reviewed. The clinical data and technical results are presented.
RESULTS: Ten patients with 15 aneurysms were treated with double LVIS stents, with a 100% technical success rate. No mortality was observed. Immediate angiographic outcome evaluation showed complete occlusion in 13 aneurysms (86.7%) and neck remnants in 2 aneurysms (13.3%).
CONCLUSION: Double LVIS stents are safe and effective in the treatment of intracranial aneurysms, especially complex aneurysms.
PMID: 30630046 [PubMed - as supplied by publisher]