ABSTRACT
Purpose
To compare surface properties of 2 brands of pre‐polymerized resin blocks for complete dentures (CAD/CAM PMMA) to conventional heat‐polymerized PMMA.
Materials and Methods
A total of 45 rectangular specimens (25 × 25 × 3 mm) were fabricated from 3 brands of PMMA (n = 15/group): AvaDent CAD/CAM PMMA, Tizian‐Shütz CAD/CAM PMMA, Meliodent conventional PMMA. Specimens were examined for wettability using the sessile drop method, surface roughness using a digital contact profilometer, and microhardness using Vickers hardness number. Statistical analysis was performed using one‐way ANOVA and Tukey pairwise multiple comparisons. P‐values of ≤ 0.05 were considered significant.
Results
AvaDent specimens demonstrated the highest mean of contact angle (72.87 ± 48°) and the highest mean of Vickers hardness number (20.62 ± 0.33). The conventional heat‐polymerized specimens showed the highest mean of surface roughness (0.22 ± 0.071 μm). Tizian‐Schütz specimens showed the lowest mean of surface roughness (0.12 ± 0.02 μm).
Conclusions
As CAD/CAM PMMA groups exhibited significantly more favorable surface properties in comparison to the conventional heat‐polymerized groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in surface properties.