Αρχειοθήκη ιστολογίου

Πέμπτη 14 Φεβρουαρίου 2019

A simple, rapid and low cost reversed-phase dispersive liquid-liquid microextraction for the determination of Na, K, Ca and Mg in biodiesel

Publication date: 1 July 2019

Source: Talanta, Volume 199

Author(s): Emilene C. Lourenço, Eduardo Eyng, Paulo R.S. Bittencourt, Fabio A. Duarte, Rochele S. Picoloto, Éder L.M. Flores

Abstract

In this work a method based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) as sample preparation for the extraction and preconcentration of Na, K, Ca and Mg in biodiesel samples was developed. The analytes determination was performed by flame atomic absorption spectrometry (FAAS), operating in emission mode for Na and K and in absorption mode for Ca and Mg. The extraction/preconcentration step of the analytes was performed by using a mixture of dispersant and extractant solvents (isopropanol and HNO3, respectively) and the aqueous phase containing the analytes was separated by centrifugation. Some parameters such as sample mass, type and volume of dispersant and extractant solutions, HNO3 concentration (extraction solution), use of ultrasound, centrifugation time and temperature were evaluated. During the optimization of RP-DLLME, biodiesel samples were spiked with a multi-element biodiesel B100 (Conostan®) with final concentration of 1.0 μg g−1 of the analytes. Analytes determination was performed by FAAS using external calibration with aqueous reference solutions. The limits of quantification (LOQ) for Na, K, Ca and Mg were 0.04; 0.02; 0.05 and 0.08 µg kg respectively. The accuracy was evaluated by recovery tests, which ranged from 93.9% to 108.1%, with relative standard deviation lower than 3% for all analytes. Then, the proposed method was applied for analytes determination in five biodiesel samples produced from different raw materials. Comparing to conventional methods for elements determination in biodiesel (e.g., dilution with organic solvent, sample digestion, etc.), RP-DLLME combined to FAAS is simple, low cost, low reagents consumption and provides LOQs values significantly below compared to the limits established in the legislation for these elements in biodiesel.

Graphical abstract

fx1



from A via a.sfakia on Inoreader http://bit.ly/2BzG7cW

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,

Αναζήτηση αυτού του ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader