Abstract
Purpose
The purpose of this study was to evaluate the impact of the rescanning of mesh holes of different diameters on the accuracy of an intraoral scanner (IOS) used to digitize an ear model.
Materials and methods
An ear model was digitized using an intraoral scanner (Medit i500) to obtain a reference mesh. A baseline experimental scan was created by editing a duplicate of the reference mesh using the cut-out tool of the IOS software. Three equal groups were created based on the diameter of the cut-out areas: 2-mm (G1), 5mm (G2), and 8-mm (G3) (n = 15). The cut-out areas were rescanned and a total of 45 digital files were exported. The discrepancy between the reference and the experimental digital scans was measured using the root mean square calculation (RMS). The data were analyzed by a Kruskal–Wallis test followed by a post hoc Dunn's test with Bonferroni correction.
Results
The trueness values ranged from 19.53 to 27.13 μm. There were significant differences in the RMS error values among the groups tested (p<.001) and post hoc multiple comparisons showed significant differences between the G1 and G2 groups (p = .04), G1 and G3 groups (p<.001), and G2 and G3 groups (p = .004). Overall, the precision values ranged from 4.93 to 7.73 μm and significant differences in the RMS values were only found between the G1 and G2 groups (p = .014).
Conclusions
Mesh hole rescanning affected the scanning accuracy (trueness and precision) of the IOS tested. The larger the diameter of the mesh holes, the less the trueness of the IOS tested. The precision values seemed to be less affected compared with the trueness by the cut-out and rescanning procedures.
This article is protected by copyright. All rights reserved
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,