Αρχειοθήκη ιστολογίου

Πέμπτη 6 Ιανουαρίου 2022

Characterizing Polarity Sensitivity in Cochlear Implant Recipients: Demographic Effects and Potential Implications for Estimating Neural Health

xlomafota13 shared this article with you from Inoreader

Abstract

Stimulus polarity can affect both physiological and perceptual measures in cochlear-implant recipients. Large differences between polarities for various outcome measures (e.g., eCAP threshold, amplitude, or slope) theoretically reflect poorer neural health, whereas smaller differences reflect better neural health. Therefore, we expect large polarity effects to be correlated with other measures shown to contribute to poor neural health, such as advanced age or prolonged deafness. Our earlier studies using the electrically evoked compound action potential (eCAP) demonstrated differences in polarity effects between users of Cochlear and Advanced Bionics devices when device-specific clinical pulse designs were used. Since the stimuli differed slightly between devices, the first goal of this study was to determine whether small, clinically relevant differences in pulse phase duration (PD) have a significant impact on eCAP polarity effects to potentially explain the de vice differences observed previously. Polarity effects were quantified as the difference in eCAP thresholds, mean normalized amplitudes, and slope of the amplitude growth function obtained for anodic-first versus cathodic-first biphasic pulses. The results showed that small variations in PD did not explain the observed differences in eCAP polarity effects between devices. Therefore, eCAP polarity sensitivity measures are relatively robust to small differences in pulse parameters. However, it remains unclear what underlies the observed manufacturer differences, which may limit the utility of eCAP polarity sensitivity measures. The second goal was to characterize polarity sensitivity in a large group of CI recipients (65 ears) to relate polarity sensitivity to age and duration of deafness as a proxy for neural health. The same pulse parameters were used for both device groups. The only significant predictors of eCAP polarity effects were age for threshold and amplitude polarity effect s for Cochlear recipients and age and duration of deafness for slope for AB recipients. However, three of these four correlations were in the opposite direction of what was expected. These results suggest that eCAP polarity sensitivity measures likely reflect different mechanisms than the effects that age and duration of deafness induce on the peripheral auditory system.

View on the web

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,

Αναζήτηση αυτού του ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader