Abstract
Introduction
Thyroid Imaging Reporting and Data Systems (TI‐RADS) including a modified system (M TI‐RADS) and American College Radiology (ACR) TI‐RADS are introduced. Correlation studies between both TI‐RADSs and The Bethesda System for Reporting Thyroid Cytology (TBSRTC) for Ultrasound‐guided fine‐needle aspiration (US‐FNA) cases with surgical follow‐up (SFU) are presented.
Materials and Methods
Three hundred and forty six thyroid US‐FNA cases performed at the US‐FNA clinic of Stony Brook University Hospital by an Ultrasound‐trained interventional Cytopathologist between December 1, 2014 to February 28, 2018 were reviewed. All ultrasound images from 346 cases were evaluated and assigned M TI‐RADS scores based on ultrasound features present in Table 1. One hundred and fifty four cases from Dcember 1, 2014 to February 28, 2016 were assigned scores using ACR TI‐RADS.TBSRTC category along with SFU data was collected and correlated with both TI‐RADS scores by using Pearson's correlation coefficient (r). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy for M TI‐RADS and TBSRTC were also calculated using SFU diagnosis as a gold standard. McNemar test was applied to evaluate the significance of the difference between M TI‐RADS and TBSRTC.
Results
Based on 346 thyroid nodules studied, the overall r‐value between M TI‐RADS scores and TBSRTC categories is 0.465. The r‐values between Composition, Echogenicity, Shape, Margin, Echogenic foci, the summary points, and the converted TR level of ACR TI‐RADS and TBSRTC are 0.145, 0.042, 0.259, 0.310, 0.405, and 0.379, respectively. Fifty (14.5%) cases have SFUs. Considering TI‐RADS 5&6 and TBSRTC 5&6 as positives, and TI‐RADS 2 and TBSRTC 2 as negatives, the Sensitivity, Specificity, PPV, NPV, and accuracy are 96%, 53%, 76%, 89%, 79% for TI‐RADS vs 100%, 93%, 96%, 100%, 97% for TBSRTC, respectively (P = .038). The data for indeterminate cases are summarized.
Conclusion
Both TI‐RADSs could be helpful to a moderate degree. M TI‐RADS appeared to correlate to TBSRTC slightly better than that of ACR TI‐RADS. TBSRTC is significantly more accurate than M TI‐RADS for the majority of determined cases.
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,