Αρχειοθήκη ιστολογίου

Πέμπτη 31 Μαρτίου 2022

Key Issues in Use of Prophylactic Steroids to Prevent Hypocalcemia and Voice Dysfunction After Thyroidectomy—Reply

paythelady.61 shared this article with you from Inoreader

jamanetwork.com

In Reply We thank Ms Kane and colleagues for their feedback on our article.
View on the web

Vestibular Rehabilitation for Unilateral Peripheral Vestibular Deficits

paythelady.61 shared this article with you from Inoreader

jamanetwork.com

In the 1940s, Cawthorne and Cooksey noted that patients with unilateral vestibular dysfunctions who exercised coped better with their symptoms and made a faster recovery than patients who did not exercise. These original exercise protocols were developed to treat patients with labyrinth injury resulting from head injury or surgery. Vestibular rehabilitation can be defined as a set of exercises designed to facilitate central nervous system plasticity through adaptation or by generating substitute mechanisms among patients with balance disorders, thus improving their overall stability and helping them resume their daily activities. Vestibular rehabilitation has been practiced for almost 70 years and evidence related to its efficacy and effectiveness has increased over the last 15 to 20 years. According to the Cochrane systematic review by McDonnell and Hillier, there is moderate to strong evidence that vestibular rehabilitation (movement, exercise based) is a safe and effective approach for unilateral peripheral vestibular disorders.
View on the web

Evaluation of digital construction, production and intraoral position accuracy of novel 3D CAD/CAM titanium retainers

paythelady.61 shared this article with you from Inoreader

56.jpg

Abstract

Objectives

New opportunities have arisen to manufacture three-dimensional computer-aided design/computer-aided manufacturing (3D CAD/CAM) retainers from titanium blocks by digital cutting technology. These novel technologies need to fulfill requirements regarding digital planning and position accuracy. The aim of the present study was to investigate the digital construction, the CAD/CAM production and the intraoral positioning accuracy of custom-manufactured novel 3D CAD/CAM titanium retainers.

Materials and methods

A total of 37 prime4me® RETAIN3R (Dentaurum, Ispringen, Germany) retainers were inserted to stabilize the upper anterior front teeth. Following insertion, an intraoral scan was used to record the position. The intraoral position was compared to the virtual setup using 3D superimposition software. Measurement points were evaluated in all three dimensions (horizontal, sagittal and vertical planes). Data were analyzed using Kruskal–Wallis test followed by Dunn's multiple comparison test.

Results

A total of 185 measurements were performed. The horizontal plane and the sagittal plane demonstrated a high level of positioning accuracy between the planned and the intraoral position. Statistically significant deviations between the preceding virtual setup and the intraoral situation were observed in the vertical dimension. Within the retainer, the intraoral positioning accuracy decreased for the measurement points in the direction of the distal retainer segment.

Conclusion

Based on the results, the present study shows a high level of congruence between the 3D virtually planning and the final intraoral position of the fabricated novel 3D CAD/CAM titanium retainers.

View on the web

Expert consensus on dental caries management

paythelady.61 shared this article with you from Inoreader

41368_2022_167_Fig1_HTML.png

International Journal of Oral Science, Published online: 31 March 2022; doi:10.1038/s41368-022-00167-3

Expert consensus on dental caries management
View on the web

Τετάρτη 30 Μαρτίου 2022

Comparison of stress distribution between zirconia/alloy endocrown and CAD/CAM multi-piece zirconia post-crown: three-dimensional finite element analysis

paythelady.61 shared this article with you from Inoreader

784.jpg

Abstract

Objectives

This study aimed to evaluate a digital multi-piece zirconia post-crown to restore a mandibular second molar with extensive coronal loss and limited restoration space, and to compare the stress distribution between endocrowns made of zirconia or alloy and CAD/CAM multi-piece zirconia post-crowns.

Material and methods

Four three-dimensional finite element analysis models of a mandibular second molar with extensive coronal loss and limited restoration space were created as follows: (A) intact molar; (B) zirconia endocrown restored molar; (C) multi-piece post-crown restored-molar with tapered nail; (D) multi-piece post-crown restored molar with T-shaped nail. Models C and D were divided into two subgroups according to the material type: C1/D1, zirconia; C2/D2, NiCr alloy. The maximum modified von Mises failure criterion (mvM) stresses were calculated, and the stress distribution was recorded to analyze the effects of the restoration and material types on the biomechanical properties of dentin and prosthesis.

Results

The maximum mvM stress of dentin in model B (33.80 MPa) was lower compared with models C (C1, 37.81 MPa; C2, 36.36 MPa) and D (D1, 36.34 MPa; D2, 34.97 MPa) under vertical load, but the opposite was observed under oblique load. The highest mvM stress was concentrated in the nail region located in the root canal, and the T-shaped nail values were greater than the tapered nail, whereas model D with T-shaped nail showed a lower mvM stress level in dentin compared with Model C with tapered nail.

Conclusions

The digital multi-piece zirconia post-crown is a potential approach to restore mandibular second molars with extensive coronal loss and limited restoration space.

Clinical relevance

The digital multi-piece zirconia post-crown has potential to restore mandibular second molars with extensive coronal loss and limited restoration space using an innovative approach.

View on the web

The implicated clinical factors for outcomes in 304 patients with salivary duct carcinoma: Multi‐institutional retrospective analysis in Japan

paythelady.61 shared this article with you from Inoreader

Abstract

Background

Salivary duct carcinoma (SDC) is a high-grade salivary malignancy that frequently occurs as the carcinomatous component of carcinoma ex pleomorphic adenoma. We herein examined the clinical factors affecting outcomes in a large cohort of SDC.

Methods

We selected 304 SDC cases and investigated clinical characteristics and the factors affecting outcomes.

Results

The median age of the cases examined was 68 years, the most common primary site was the parotid gland (238 cases), and there was a male predominance (M/F = 5:1). Outcomes were significantly worse when the primary tumor site was the minor salivary glands (SG) than when it was the major SG. Outcomes were also significantly worse in pN(+) cases (161 cases) than in pN0 cases, particularly those with a metastatic lymph node number ≥11. The cumulative incidence of relapse and distant metastases was significantly higher in stage IV cases than in stage 0–III cases.

Conclusions

The absolute number of lymph node metastases, higher stages, and the minor SG as the primary tumor site were identified as factors affecting the outcome of SDC.

View on the web

From a Slave to a Surgeon: David Kearney McDonogh, the First Black Otolaryngologist

paythelady.61 shared this article with you from Inoreader
Otolaryngology–Head and Neck Surgery, Ahead of Print.
David McDonogh, born into chattel slavery in Louisiana in the early 1800s, accomplished the unfathomable by becoming the first Black otolaryngologist in the United States of America. With tireless determination and profound intellect, Dr McDonogh surmounted immeasurable adversity along his improbable journey to freedom and success as an eye, ear, nose, and throat doctor in New York. His doctorate in medicine was posthumously awarded to his great-great-granddaughter in 2018 by the Columbia University Vagelos College of Physicians and Surgeons. In this History of Otolaryngology piece, we share his extraordinary story.
View on the web

Systemic Steroids for Otolaryngology–Head and Neck Surgery Disorders: An Evidence-Based Primer for Clinicians

paythelady.61 shared this article with you from Inoreader
Otolaryngology–Head and Neck Surgery, Ahead of Print.
ObjectiveTo offer pragmatic, evidence-informed guidance on the use of systemic corticosteroids (SCS) for common otolaryngologic disorders.Data SourcesPubMed, Cochrane Library, and American Academy of Otolaryngology–Head and Neck Surgery Foundation clinical practice guidelines.Review MethodsA comprehensive search of published literature through November 2021 was conducted on the efficacy of SCS, alone or in combination with other treatments, for managing disorders in otolaryngology and the subdisciplines. Clinical practice guidelines, systematic reviews, and randomized controlled trials, when available, were preferentially retrieved. Interventions and outcomes of SCS use were compiled to generate summary tables and narrative synthesis of findings.ConclusionsEvidence on the effectiveness of SCS varies widely across otolaryngology disorders. High-level evidence supports SCS use for Bell's palsy, sinonasal polyposis, a nd lower airway disease. Conversely, evidence is weak or absent for upper respiratory tract infection, eustachian tube dysfunction, benign paroxysmal positional vertigo, adenotonsillar hypertrophy, or nonallergic rhinitis. Evidence is indeterminate for acute laryngitis, acute pharyngitis, acute sinusitis, angioedema, chronic rhinosinusitis without polyps, Ménière's disease, postviral olfactory loss, postoperative nerve paresis/paralysis, facial pain, and sudden sensorineural hearing loss.Implications for PracticeClinicians should bring an evidence-informed lens to SCS prescribing to best counsel patients regarding the risks, anticipated benefits, and limited data on long-term effects. Alternate routes of corticosteroid administration—such as sprays, drops, inhalers, and intralesional injections—may be preferable for many disorders, particularly those that are self-limited or require a prolonged duration of therapy. Prudent use of SCS reduces the risk of medication-related ad verse effects. Clinicians who are conversant with high-level evidence can achieve optimal outcomes and stewardship when prescribing SCS.
View on the web

A Novel External Auditory Canal Squamous Cell Carcinoma Cell Line Sensitive to CDK4/6 Inhibition

paythelady.61 shared this article with you from Inoreader
Otolaryngology–Head and Neck Surgery, Ahead of Print.
ObjectiveTo characterize cell line CAE606 derived from a squamous cell carcinoma (SCC) of the external auditory canal (EAC) and to show its usefulness as a model for testing candidate therapeutic agents.Study DesignPreclinical translational research.SettingBiomedical research institute.MethodsThe cell line was initiated from a moderately differentiated T2N0M0 EAC SCC. We studied its histologic and genetic features as well as growth and invasion parameters. Sensitivity to cell CDK4/6 cell cycle inhibitor palbociclib was analyzed.ResultsCAE606 cells expressed heavy molecular weight cytokeratin, p63, and vimentin. The population doubling time was 25.8 hours, and the cells showed fast collective cell migration in a wound-healing assay. Short tandem repeat analysis confirmed it to be derived from the primary tumor of the patient. Next-generation sequencing revealed alterations in cell cycle regulation genes, including inact ivating mutations in CDKN2A and TP53 and high-level amplification of CCND1 and EGFR. CAE606 showed a strong decrease of phospo-Rb expression upon exposure to the CDK4/6 inhibitor palbociclib, causing significant growth inhibition with an IC50 of 0.46 µM.ConclusionThis is the first report of a stable EAC SCC cell line. Its genetic features make it a useful tool for preclinical testing of new therapeutic agents for EAC SCC, particularly those targeting cell cycle regulation in combination with radio- and chemotherapy or other specific signaling pathway inhibitors.
View on the web

Subclonal heterogeneity sheds light on the transformation trajectory in IGLV3-21R110 chronic lymphocytic leukemia

paythelady.61 shared this article with you from Inoreader

41408_2022_650_Fig1_HTML.png

Blood Cancer Journal, Published online: 30 March 2022; doi:10.1038/s41408-022-00650-4

Subclonal heterogeneity sheds light on the transformation trajectory in IGLV3-21R110 chronic lymphocytic leukemia
View on the web

Comparison of the Osteogenic Effectiveness of an Autogenous Demineralized Dentin Matrix and Bio-Oss® in Bone Augmentation: A Systematic Review and Meta-analysis

paythelady.61 shared this article with you from Inoreader

1-s2.0-S0266435621X00113-cov150h.gif

Publication date: Available online 29 March 2022

Source: British Journal of Oral and Maxillofacial Surgery

Author(s): Yanfei Li, Wanhang Zhou, Peiyi Li, Qipei Luo, Anqi Li, Xinchun Zhang

View on the web

Cancer Risk Associated with Continuous Positive Airway Pressure: A National Study

paythelady.61 shared this article with you from Inoreader

Objective

In 2021 the U.S. FDA issued a Class 1 safety recall notice for specific devices due to a risk of carcinogen exposure. The objective of this study was to evaluate reports of cancer linked to CPAP devices to understand implications for the field of sleep medicine.

Methods

Cases of cancer involving CPAP devices were retrieved from the MAUDE database from 2014 to 2021 and analyzed with descriptive statistics.

Results

A total of 2571 patient injuries were associated with CPAP. Reports of cancer (n = 209; 4.62%) were the second most commonly documented patient problem associated with CPAP, although 1950 (43.13%) patients had a device problem without an associated injury. Of the 209 cancer cases associated with CPAP, 200 (95.7%) of the adverse event reports were received by the FDA in 2021. There were 174 (9.15%) descriptions of the CPAP polyurethane sound abatement foam degrading in association with a cancer diagnosis, but degradation was more commonly not associated with malignancy (n = 1728; 90.85%). Other frequently documented CPAP device problems included broken devices (n = 279; 6.92%), fire (n = 182; 4.51%), and patient–device incompatibility (n = 144; 3.57%).

Conclusion

Malignancy associated with CPAP devices has been reported; however, future studies are required to establish causation. Given 95.7% of those documented cases were reported in 2021, otolaryngologists should be prepared to discuss the risks of carcinogenesis associated with CPAP. The otolaryngology community should also be aware of the potential bandwagon effect and the implications for CPAP compliance.

Level of Evidence

4 Laryngoscope, 2022

View on the web

Αναζήτηση αυτού του ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader